Dedicated to Special Inspections in NYC

AM & Associates provides a full range of New York City Special Inspections services to support our clients’ needs. This includes mechanical special inspections, welding inspections, sprinkler special inspections, structural inspections, as well as many other inspection types. This extensive range of inspection services has allowed the firm to become a single source provider to its clients throughout the life cycle of their buildings, from initial infrastructure to ongoing operations and renovations. The firm continues to evolve and expand our services throughout the New York metropolitan area.

Structural Inspections

Find out more about Structural Inspections

Mechanical Inspections

Find out more about Mechanical Inspections

Civil Inspections

Find out more about Civil Inspections

Architectural Inspections

Find out more about Architectural Inspections

New York City Special Inspections Provided

  • Structural Steel – Welding
  • Structural Steel – Details
  • Structural Steel – High Strength Bolting
  • Structural Cold-Formed Steel
  • Concrete – Cast-In-Place
  • Concrete – Precast
  • Concrete – Prestressed
  • Masonry
  • Wood – Installation of High-Load Diaphragms
  • Wood – Installation of Metal-Plate-Connected Trusses
  • Wood – Installation of Prefabricated I-Joists
  • Subgrade Inspection
  • Subsurface Conditions – Fill Placement & In-Place
  • Subsurface Investigations (Borings/Test Pits)
  • Deep Foundation Elements
  • Helical Piles
  • Vertical Masonry Foundation Elements
  • Wall Panels, Curtain Walls, and Veneers
  • Sprayed fire-resistant material
  • Mastic and Intumescent Fire-resistant Coatings
  • Exterior Insulation and Finish Systems (EIFS)
  • Alternative Materials  – OTCR Buildings Bulletin #
  • Smoke Control Systems
  • Mechanical Systems
  • Fuel-Oil Storage and Fuel-Oil Piping Systems
  • High-Pressure Steam Piping (Welding)
  • Structural Stability – Existing Buildings
  • Excavations—Sheeting, Shoring, and Bracing
  • Mechanical Demolition
  • Underpinning
  • Raising and Moving of a Building
  • Soil Percolation Test Private On-Site Storm Water Drainage Disposal – Private On-Site Storm Water
  • Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities Installation
  • Individual On-Site Private Sewage Disposal Systems Installation
  • Soil Percolation Test – Individual On-Site Private Sewage Disposal Systems
  • Sprinkler Systems
  • Standpipe Systems
  • Heating Systems
  • Chimneys
  • Fire-resistant Penetrations and Joints
  • Aluminum Welding
  • Flood Zone Compliance (attach FEMA elevation/dry
  • Luminous Egress Path Markings
  • Emergency and Standby Power Systems (Generators)
  • Post-installed Anchors (BB# 2014-018, 2014-019)
  • Seismic Isolation Systems
  • Concrete Design Mix
  • Concrete Sampling and Testing
  • Preliminary
  • Footing and Foundation
  • Lowest Floor Elevation
  • Structural Wood Frame
  • Energy Code Compliance Inspections
  • Fire-Resistance Rated Construction
  • Public Assembly Emergency Lighting
  • Final